Trotec HG110 Hygrostat with Jack Plug

Description

This room hygrometer is suitable for humidity-dependent control of the TTK170ECO or other dehumidifiers with a 6.35 mm jack for external connection, for example for unattended drying processes where a target humidity must not be undershot (for instance, with fresh plaster or plastering work) or to reduce power consumption when a too low humidity is not necessary. 
 
The HG 110 features a 6.35 mm jack plug, operates in the low voltage range, and is designed for a maximum load of 2 A. The three-meter long cable allows the measurement point to be different from the location of the dehumidifier.
 
 
application examples
 
It serves as a two-point controller for regulating relative humidity, for example, on indoor construction sites, in basements, in climate cabinets, or for controlled dehumidification of office and computer rooms. Other areas of application include storage for goods or food, cold storage for fruits and vegetables, greenhouses of horticultural businesses, textile industry, paper and printing industry, film industry, hospitals. Wherever humidity needs to be regulated or monitored, this humidity controller with the corresponding dehumidifier can be used. 
 
 
Functionality and Installation Location
 
The installation location should be chosen in such a way that a representative measurement of humidity is ensured, i.e., the humidity measurement values at the installation location should correspond to those of the room, and the hygrometer should be in the airflow. The room hygrometer reacts quickly and accurately to changes in humidity. By adjusting the setpoint knob, the lever system is engaged in such a way that when the set humidity is reached, the internal microswitch is activated.
 
 
Technical data
 
Measuring range 40 - 90 % relative humidity
Measurement accuracy +-3%
suitable ambient temperature 0 - 60° C
suitable ambient humidity 40 - 90 %
Tension 24 V
max. switching load 2 A
Cable length 3 Meters
connector 6.35 mm jack 1/4"
Protection class IP20
guarantee 2 years
product form

item number: T6100002044
Barcode: 4052138011072

This room hygrometer is suitable for humidity-dependent control of the TTK170ECO or other dehumidifiers with a 6.35 mm jack for... learn more

5 in stock

Fr. 98.00 VAT included

    Versandkosten: <5 kg: 10.- | >5-30 kg: 14.- | >30 kg: 69.-
    Zahlungsarten: Twint, Paypal, Visa, Master, Amex, Maestro, Apple, Google

    Description

    This room hygrometer is suitable for humidity-dependent control of the TTK170ECO or other dehumidifiers with a 6.35 mm jack for external connection, for example for unattended drying processes where a target humidity must not be undershot (for instance, with fresh plaster or plastering work) or to reduce power consumption when a too low humidity is not necessary. 
     
    The HG 110 features a 6.35 mm jack plug, operates in the low voltage range, and is designed for a maximum load of 2 A. The three-meter long cable allows the measurement point to be different from the location of the dehumidifier.
     
     
    application examples
     
    It serves as a two-point controller for regulating relative humidity, for example, on indoor construction sites, in basements, in climate cabinets, or for controlled dehumidification of office and computer rooms. Other areas of application include storage for goods or food, cold storage for fruits and vegetables, greenhouses of horticultural businesses, textile industry, paper and printing industry, film industry, hospitals. Wherever humidity needs to be regulated or monitored, this humidity controller with the corresponding dehumidifier can be used. 
     
     
    Functionality and Installation Location
     
    The installation location should be chosen in such a way that a representative measurement of humidity is ensured, i.e., the humidity measurement values at the installation location should correspond to those of the room, and the hygrometer should be in the airflow. The room hygrometer reacts quickly and accurately to changes in humidity. By adjusting the setpoint knob, the lever system is engaged in such a way that when the set humidity is reached, the internal microswitch is activated.
     
     
    Technical data
     
    Measuring range 40 - 90 % relative humidity
    Measurement accuracy +-3%
    suitable ambient temperature 0 - 60° C
    suitable ambient humidity 40 - 90 %
    Tension 24 V
    max. switching load 2 A
    Cable length 3 Meters
    connector 6.35 mm jack 1/4"
    Protection class IP20