{"product_id":"ide-60-d-trotec-oelheizgeblaese-direkt","title":"IDE 60 D Trotec direct oil-fired fan heater","description":"\u003cdiv style=\"line-height: 1.6; max-width: 900px; margin: 0 auto;\"\u003e\n\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background-color: #F6F6F6; padding: 25px; border-left: 8px solid #BCCF00; margin-bottom: 30px;\"\u003e\n\n\u003ch2 style=\"color: #000; margin-top: 0;\"\u003eThe powerful direct-fired oil heater for large halls and construction sites\u003c\/h2\u003e\n\n\n\u003cp style=\"font-size: 1.1em; font-weight: bold; margin: 0;\"\u003e60 kW heating capacity, 1,100 m³\/h airflow and a generous 56-liter tank – professional heating for demanding applications.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- INTRO FLEX --\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 2; min-width: 300px;\"\u003e\n\n\u003cp\u003eThe IDE 60 D direct-fired oil heater from TROTEC was developed for the fast and powerful heating of large, well-ventilated spaces and covered outdoor areas. With a nominal heat output of 60 kW, it is ideal for professional applications on construction sites, in warehouses, workshops and agricultural buildings.\u003c\/p\u003e\n\n\n\u003cp\u003eThe heater combines high heat output with a robust construction and practical features. The durable, double-coated steel housing and high-quality stainless steel combustion chamber are designed for use under demanding working conditions. The integrated fuel tank holds 56 liters and features a level indicator, allowing the available fuel quantity to be checked at any time.\u003c\/p\u003e\n\n\n\u003cp\u003eThe integrated thermostat ensures comfortable operation and allows the desired temperature to be set. An additional connection for an external thermostat is also available. This allows the temperature to be monitored at a location away from the heater and the heating operation to be controlled accordingly.\u003c\/p\u003e\n\n\n\u003cp\u003eThe powerful axial fan delivers up to 1,100 m³ of air per hour and distributes the generated heat directly into the surrounding area. An electronic flame safeguard and an integrated overheating protection ensure additional operational safety. Thanks to the stable chassis with wheels and a transport handle, the heater can be easily moved within the area of use despite its high power output.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- VORTEILE --\u003e\n\n\u003cdiv style=\"flex: 1; min-width: 250px; background-color: #F6F6F6; padding: 20px; border-radius: 8px; border: 1px solid #ddd;\"\u003e\n\n\u003cstrong style=\"color: #000; display: block; margin-bottom: 10px;\"\u003eFeatures:\u003c\/strong\u003e\n\n\u003cul style=\"padding-left: 18px; margin: 0; font-size: 0.9em;\"\u003e\n\n\t\u003cli\u003eDirect nominal heat output of 60 kW\u003c\/li\u003e\n\n\t\u003cli\u003eAirflow of up to 1,100 m³\/h\u003c\/li\u003e\n\n\t\u003cli\u003eIntegrated 56-liter fuel tank\u003c\/li\u003e\n\n\t\u003cli\u003eFuel level indicator\u003c\/li\u003e\n\n\t\u003cli\u003eElectronic flame safeguard\u003c\/li\u003e\n\n\t\u003cli\u003eIntegrated overheating protection\u003c\/li\u003e\n\n\t\u003cli\u003eIntegrated thermostat\u003c\/li\u003e\n\n\t\u003cli\u003eConnection for external thermostat\u003c\/li\u003e\n\n\t\u003cli\u003eRobust, double-coated steel housing\u003c\/li\u003e\n\n\t\u003cli\u003eStainless steel combustion chamber\u003c\/li\u003e\n\n\t\u003cli\u003eAxial fan\u003c\/li\u003e\n\n\t\u003cli\u003eChassis with wheels\u003c\/li\u003e\n\n\t\u003cli\u003ePractical transport handle\u003c\/li\u003e\n\n\t\u003cli\u003eProtection rating IPX4\u003c\/li\u003e\n\n\t\u003cli\u003eSuitable for large, well-ventilated spaces\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- DIREKTE BEHEIZUNG --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003eDirect heating with 100% heat output\u003c\/h4\u003e\n\n\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003cp\u003eThe IDE 60 D operates on the principle of direct oil heating. Unlike indirectly fired heaters, it has no flue connection for the separate discharge of combustion gases. The generated heat is released directly into the surroundings. This means that the entire generated heat output is available directly at the place of use.\u003c\/p\u003e\n\n\n\u003cp\u003eDuring the heating process, the fuel is atomized in the combustion chamber, ignited and continuously burned. Part of the air drawn in is compressed and used to supply the fuel. At the same time, the fan delivers the required combustion air and generates the airflow in which the hot combustion gases are mixed. The heated air is then directed directly into the room through the air outlet.\u003c\/p\u003e\n\n\n\u003cp\u003eThis operating principle enables immediate heat release without additional heat losses through an exhaust flue. The thermal efficiency is 100% of the generated heat output. This makes the IDE 60 D particularly suitable for applications where a large amount of heat must be made available quickly and directly.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- EINSATZGEBIETE --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003eIdeal for large spaces and demanding applications\u003c\/h4\u003e\n\n\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003cp\u003eWith its heat output of 60 kW, the IDE 60 D is designed for heating large, well-ventilated areas. It is particularly suitable for commercial and industrial applications where a powerful and mobile heat source is required.\u003c\/p\u003e\n\n\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\n\n\u003cul style=\"padding-left: 20px;\"\u003e\n\n\t\u003cli\u003eConstruction sites and covered construction site areas\u003c\/li\u003e\n\n\t\u003cli\u003eLarge warehouses and storage areas\u003c\/li\u003e\n\n\t\u003cli\u003eWorkshops and production areas\u003c\/li\u003e\n\n\t\u003cli\u003eAgricultural halls and farm buildings\u003c\/li\u003e\n\n\t\u003cli\u003eGreenhouses with sufficient fresh air supply\u003c\/li\u003e\n\n\t\u003cli\u003eTents and covered event areas\u003c\/li\u003e\n\n\t\u003cli\u003eTemporary heating of large workspaces\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003cp\u003eThe device is designed for use without frequent changes of location. The integrated chassis nevertheless allows for easy transport within the respective work area. Thanks to the high heat output, even large air volumes can be heated quickly.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- THERMOSTAT --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003eComfortable temperature control with integrated thermostat\u003c\/h4\u003e\n\n\n\u003cp\u003eThe integrated thermostat allows for demand-based control of the heating operation. The desired temperature can be set directly on the device. This allows the heat supply to be adapted to the respective requirements without the heater having to be constantly monitored manually.\u003c\/p\u003e\n\n\n\u003cp\u003eFor additional flexibility, the IDE 60 D features a connection for an external thermostat. This allows the temperature to be monitored at a different location in the area to be heated. This is particularly advantageous if the heater is placed, for example, in a corner of a hall or outside the actual work area.\u003c\/p\u003e\n\n\n\u003cp\u003eExternal temperature monitoring enables more demand-based control and supports comfortable heating operation even in larger spaces. The external thermostat is available separately as an accessory.\u003c\/p\u003e\n\n\u003c!-- BRENNSTOFFTANK --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003eGenerous 56-liter fuel tank\u003c\/h4\u003e\n\n\n\u003cp\u003eThe integrated fuel tank with a capacity of 56 liters provides a generous fuel reserve for longer heating applications. A practical level indicator allows the tank contents to be checked at any time and makes it easier to plan the next refueling.\u003c\/p\u003e\n\n\n\u003cp\u003eThe fuel supply is provided by an integrated compressor system. The IDE 60 D can be operated with heating oil EL, diesel or kerosene. This allows the fuel supply to be flexibly adapted to availability and the respective operational requirements.\u003c\/p\u003e\n\n\n\u003cp\u003eAt a maximum fuel consumption of 5.7 liters per hour, the calculated operating time is approximately 9.8 hours with a completely full tank. The actual operating time depends on the respective operating mode and the required heat output.\u003c\/p\u003e\n\n\u003c!-- SICHERHEIT --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003eReliable safety equipment\u003c\/h4\u003e\n\n\n\u003cp\u003eWith a heat output of 60 kW, reliable safety equipment is particularly important. The IDE 60 D therefore features an electronic flame safeguard that monitors the combustion process. If a fault is detected or the flame goes out, the fuel supply is interrupted accordingly.\u003c\/p\u003e\n\n\n\u003cp\u003eIn addition, an integrated safety thermostat protects the device from overheating. If the permissible operating temperature is exceeded, the safety device intervenes. In the event of corresponding overheating, the additional overheating protection can shut down the device completely.\u003c\/p\u003e\n\n\n\u003cp\u003eThe IPX4 protection rating provides protection against splashing water from all directions. The robust housing and high-quality combustion chamber support reliable use in the intended professional application area.\u003c\/p\u003e\n\n\u003c!-- SICHERHEITSHINWEISE --\u003e\n\n\u003cdiv style=\"background-color: #F6F6F6; padding: 20px; border-left: 6px solid #BCCF00; margin: 25px 0;\"\u003e\n\n\u003cstrong style=\"display: block; margin-bottom: 10px;\"\u003eImportant operating instructions:\u003c\/strong\u003e\n\n\u003cp\u003eThe IDE 60 D is a direct-fired oil heater. With this type of heating, not only heat but also combustion gases are released directly into the surroundings. Furthermore, additional moisture is generated during combustion.\u003c\/p\u003e\n\n\n\u003cp\u003eThe device may therefore only be operated in covered outdoor areas or in sufficiently ventilated indoor spaces. A continuous supply of fresh air and sufficient discharge of combustion gases must be ensured at all times. An air exchange rate of at least two air changes per hour is required for operation.\u003c\/p\u003e\n\n\n\u003cp\u003eThe device is not suitable for use in enclosed, insufficiently ventilated spaces with people or animals. Due to the moisture generated, it must also not be used for construction drying.\u003c\/p\u003e\n\n\n\u003cp\u003eThe hot surfaces and air outlet must not be touched during operation. The heater must be positioned at the prescribed safety distances. Due to the operating noise of 78 dB(A) at a distance of one meter, suitable hearing protection must be worn.\u003c\/p\u003e\n\n\n\u003cp\u003eThe device must not be operated in explosion-hazardous areas or in the immediate vicinity of highly flammable substances. Be sure to read the complete operating instructions before commissioning.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- MOBILITÄT --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003eStable chassis for flexible use\u003c\/h4\u003e\n\n\n\u003cp\u003eThe IDE 60 D is equipped with a stable chassis and wheels. This allows the powerful heater to be easily moved within the area of use when required. The practical transport handle makes maneuvering easier and assists with handling when moving the device.\u003c\/p\u003e\n\n\n\u003cp\u003eWith an empty weight of 28.5 kg with an empty tank, the heater remains relatively easy to transport despite its high power output. The chassis ensures a stable position and makes positioning at the desired place of use easier.\u003c\/p\u003e\n\n\n\u003cp\u003eThe robust, double-coated steel housing and stainless steel combustion chamber are designed for professional use. Together with the generous tank volume and high heat output, the IDE 60 D offers a reliable solution for regular heating applications in large spaces.\u003c\/p\u003e\n\n\u003c!-- TECHNISCHE DATEN --\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 30px; font-size: 0.95em;\"\u003e\n\n\t\u003ctbody\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eModel\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eIDE 60 D\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eBrand\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eTROTEC\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eItem number\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e1430000074\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eHeating type\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eDirect\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eNominal heat output\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e60 kW\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eNominal heat output\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e51,600 kcal\/h\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eAirflow\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e1,100 m³\/h\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eFan\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eAxial fan\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eAir changes per hour\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eAt least 2\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eTemperature increase ΔT\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e150 °C\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eMaximum fuel consumption\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e5.7 l\/h\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eTank capacity\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e56 liters\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eFuel supply\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eCompressor\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003ePermissible fuels\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eHeating oil EL, diesel, kerosene\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eThermostat\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eIntegrated\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eConnection for external thermostat\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eYes\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eElectronic flame safeguard\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eYes\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eOverheating protection\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eYes\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eHousing material\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eSteel, double-coated\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eCombustion chamber\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eStainless steel\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eChassis\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eYes, with wheels and transport handle\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eProtection rating\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eIPX4\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eOperating temperature\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e-20 to +40 °C\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eMaximum relative humidity during operation\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e90% r.F.\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eStorage conditions\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e-20 to +40 °C, 20 to 80% r.F.\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eConnection voltage\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eCurrent consumption\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e1.5 A\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eSound level (distance 1 m)\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e78 dB(A)\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e1,140 x 550 x 680 mm\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003eWeight with empty tank\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e28.5 kg\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\t\u003ctr\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\n\t\t\t\u003ctd style=\"padding: 8px;\"\u003e2 years\u003c\/td\u003e\n\n\t\t\u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003c!-- SICHERHEITSHINWEISE --\u003e\n\n\u003ch4 style=\"color: #333; border-bottom: 2px solid #BCCF00; padding-bottom: 5px;\"\u003ePrescribed safety distances\u003c\/h4\u003e\n\n\n\u003cp\u003eFor safe operation, the IDE 60 D must be positioned at a sufficient distance from walls, objects and other potential hazards. According to the manufacturer's specifications, the following minimum distances apply:\u003c\/p\u003e\n\n\n\u003cul style=\"padding-left: 20px; margin-bottom: 25px;\"\u003e\n\n\t\u003cli\u003eTop: at least 2 m\u003c\/li\u003e\n\n\t\u003cli\u003eRear: at least 2 m\u003c\/li\u003e\n\n\t\u003cli\u003eSides: at least 2 m\u003c\/li\u003e\n\n\t\u003cli\u003eFront at the air outlet: at least 3 m\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003cp\u003eThe device must be placed on a stable, level and non-flammable surface. The air inlet and air outlet must remain clear at all times. Also ensure that the required fresh air supply and discharge of combustion gases are ensured.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n","brand":"TROTEC","offers":[{"title":"Default Title","offer_id":55630375944533,"sku":"1430000074","price":489.0,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/3679\/4197\/files\/Direkte-Oelheizung-IDE60D-Trotec.jpg?v=1793783425","url":"https:\/\/dantherm.ch\/en\/products\/ide-60-d-trotec-oelheizgeblaese-direkt","provider":"Dantherm Group AG","version":"1.0","type":"link"}